Part # Model # Type Sub Category Amps Volts Rackmount Length Cord Length Plug Type Receptacle (QTY) Local Meter Universal Upgradeable RCM-B
VP7U20A0 MUU5MGB0-24L137-2C20A9A00-S
Show Description
rPDU, Switched Outlet Level Monitoring EC, 16A OR 20A, 120V OR 208V OR 230V, 1.9kW or 3.3kW or 3.6kW, Vertical, (24) Locking IEC C13, C20, Black Powder Coat.
Show Photo
Switched Outlet Level Monitoring 16A OR 20A 120V OR 208V OR 230V 66in / 1683mm None IEC
  • Locking IEC C13 (24)
Y N Y N
VP7U11A0 MUU5M1R0-06L137-1C14A9H00-S
Show Description
rPDU, Switched Outlet Level Monitoring EC, 10A OR 15A, 120V OR 208V OR 230V, 1.4kW or 2.4kW or 2.3kW, Horizontal, (6) Locking IEC C13, C14 Inlet, Black Powder Coat.
Show Photo
Switched Outlet Level Monitoring 10A or 15A 120V OR 208V OR 230V 19in / 483mm None IEC
  • Locking IEC C13 (6)
Y N Y N
VP7G30AH MGU5MGW1-36CF13-3PS56B2A10-S-A
Show Description
rPDU, Switched Outlet Level Monitoring EC, 32A, 230/400V WYE, 22.0kW, Vertical, (36) Combination C13/C19, 10ft / 3m power cord with 3P+N+E (IP44), Black Powder Coat.
Show Photo
Switched Outlet Level Monitoring 32A 230/400V WYE 72in / 1829mm 10ft / 3m IEC Splashproof
  • Combination C13/C19 (36)
Y N Y N
VP7G30A7 MGU5MGB1-24PJ43-3PS6B2A10-S
Show Description
rPDU, Switched Outlet Level Monitoring EC, 32A, 230V, 7.3kW, Vertical, (20) Locking IEC C13, (4) Locking IEC C19, 10ft / 3m power cord with 1P+N+E (IP44), Black Powder Coat.
Show Photo
Switched Outlet Level Monitoring 32A 230V 66in / 1683mm 10ft / 3m IEC Splashproof
  • Locking IEC C13 (20)
  • Locking IEC C19 (4)
Y N Y N
VP7G30A0 MGU5MGW1-36PT63-3PS56B2A10-S-A
Show Description
rPDU, Switched Outlet Level Monitoring EC, 32A, 230/400V WYE, 22.0kW, Vertical, (30) Locking IEC C13, (6) Locking IEC C19, 10ft / 3m power cord with 3P+N+E (IP44), Black Powder Coat.
Show Photo
Switched Outlet Level Monitoring 32A 230/400V WYE 72in / 1829mm 10ft / 3m IEC Splashproof
  • Locking IEC C13 (30)
  • Locking IEC C19 (6)
Y N Y N
VP7G20A3 MGU5MGB0-36PT63-2PS56B2A10-S-A
Show Description
rPDU, Switched Outlet Level Monitoring EC, 16A, 230/400V WYE, 11.0kW, Vertical, (30) Locking IEC C13, (6) Locking IEC C19, 10ft / 3m power cord with 3P+N+E (IP44), Black Powder Coat.
Show Photo
Switched Outlet Level Monitoring 16A 230/400V WYE 66in / 1683mm 10ft / 3m IEC Splashproof
  • Locking IEC C13 (30)
  • Locking IEC C19 (6)
Y N Y N
VP7557 MG00X4B0-42IZ63-2PS56B2A10-S
Show Description
rPDU, Basic Standard, 16A, 230/400V WYE, 11.0kW, Vertical, (36) IEC C13, (6) IEC C19, 3m power cord with 3P+N+E (IP44), Black Powder Coat.
Show Photo
Basic Standard 16A 230/400V WYE 66in / 1683mm 3m IEC Splashproof
  • IEC C13 (36)
  • IEC C19 (6)
N N N N
VP7553 MG00X4B1-24IJ43-3PS6B2A10-S
Show Description
rPDU, Basic Standard, 32A, 230V, 7.3kW, Vertical, (20) IEC C13, (4) IEC C19, 3m power cord with 1P+N+E (IP44), Black Powder Coat.
Show Photo
Basic Standard 32A 230V 66in / 1683mm 3m IEC Splashproof
  • IEC C13 (20)
  • IEC C19 (4)
N N N N
VP7552 MG00X4C0-24IJ43-2C20A9A00-S
Show Description
rPDU, Basic Standard, 16A, 230V, 3.6kW, Vertical, (20) IEC C13, (4) IEC C19, C20, Black Powder Coat.
Show Photo
Basic Standard 16A 230V 48in / 1207mm None IEC
  • IEC C13 (20)
  • IEC C19 (4)
N N N N
VP7551 MG00X4A0-24IJ43-2PS6B2A10-S
Show Description
rPDU, Basic Standard, 16A, 230V, 3.6kW, Vertical, (20) IEC C13, (4) IEC C19, 3m power cord with 1P+N+E (IP44), Black Powder Coat.
Basic Standard 16A 230V 39in / 978mm 3m IEC Splashproof
  • IEC C13 (20)
  • IEC C19 (4)
N N N N
VP6UV0A3 DUR5MGB1-24CF17-2S02A9K00-S-A
Show Description
rPDU, Monitored Outlet Level EC, 22.0kW, Variable Power Configuration, Vertical, (24) Combination C13/C19, Universal Inlet, Black Powder Coat.
Show Photo
Monitored Outlet Level Variable Variable 66in / 1683mm None Universal Input
  • Combination C13/C19 (24)
Y Y Y N
VP6UV0A2 DUR5M5W1-48CF17-2S02A9K00-S-A
Show Description
rPDU, Monitored Outlet Level EC, 22.0kW, Variable Power Configuration, Vertical, (48) Combination C13/C19, Universal Inlet, Black Powder Coat.
Show Photo
Monitored Outlet Level Variable Variable 75in / 1905mm None Universal Input
  • Combination C13/C19 (48)
Y Y Y N
VP6UV0A1 DUR5M4B1-24CF17-2S02A9K00-S-A-RC
Show Description
rPDU, Monitored Outlet Level EC, Residual Current Metering Type B, 22.0kW, Variable Power Configuration, Vertical, (24) Combination C13/C19, Universal Inlet, Black Powder Coat.
Show Photo
Monitored Outlet Level Variable Variable 72in / 1829mm None Universal Input
  • Combination C13/C19 (24)
Y Y Y Y
VP6UV0A0 DUR5MGW1-30PHB7-2S02A9K00-S-A
Show Description
rPDU, Monitored Outlet Level EC, 22.0kW, Variable Power Configuration, Vertical, (18) Locking IEC C13, (12) Locking IEC C19, Universal Inlet, Black Powder Coat.
Show Photo
Monitored Outlet Level Variable Variable 72in / 1829mm None Universal Input
  • Locking IEC C13 (18)
  • Locking IEC C19 (12)
Y Y Y N
VP6UU1A0 DUR5M1R6-12CF17-1S02A0H00-S
Show Description
rPDU, Monitored Outlet Level EC, Max 11.0kW, Variable Power Configuration, Horizontal, (12) Combination C13/C19, Universal Input, Black Powder Coat.
Show Photo
Monitored Outlet Level Variable 19in / 483mm None Universal Input
  • Combination C13/C19 (12)
Y Y Y N
VP6UU0A2 DUR5MGW1-24CF17-1S02A9K00-S-A
Show Description
rPDU, Monitored Outlet Level EC, 11.0kW, Variable Power Configuration, Vertical, (24) Combination C13/C19, Universal Inlet, Black Powder Coat.
Show Photo
Monitored Outlet Level Variable Variable 72in / 1829mm None Universal Input
  • Combination C13/C19 (24)
Y Y Y N
VP6UU0A1 DUR5MGW1-24CF17-1S02A9K00-S-A-RC
Show Description
rPDU, Monitored Outlet Level EC, Residual Current Metering Type B, 11.0kW, Variable Power Configuration, Vertical, (24) Combination C13/C19, Universal Inlet, Black Powder Coat.
Show Photo
Monitored Outlet Level Variable Variable 72in / 1829mm None Universal Input
  • Combination C13/C19 (24)
Y Y Y Y
VP6UU0A0 DUR5M4W1-36PT67-1S02A9K00-S-A
Show Description
rPDU, Monitored Outlet Level EC, 11.0kW, Variable Power Configuration, Vertical, (30) Locking IEC C13, (6) Locking IEC C19, Universal Inlet, Black Powder Coat.
Show Photo
Monitored Outlet Level Variable Variable 72in / 1829mm None Universal Input
  • Locking IEC C13 (30)
  • Locking IEC C19 (6)
Y Y Y N
VP6UA0A0 JMUR5MIZ1-36CF13-8HW56A9BXX-S
Show Description
rPDU, Monitored Outlet Level, 80A, 200-240/346-415V WYE, 57.6kW, Vertical, (36) Combination C13/C19, Hardwired, Black Powder Coat.
Show Photo
Monitored Outlet Level 80A 240/415V WYE 66in / 1683mm None Hardwired
  • Combination C13/C19 (36)
Y N Y N
VP6U62A2 JMUR5MZA1-24CF13-6PS56B4H10-S-A
Show Description
rPDU, Outlet Level Monitoring, 60/63A, 200-240/346-415V WYE, 43.4kW, Horizontal, (24) Combination C13/C19, 10ft / 3m power cord with 3P+N+E (IP44), Black Powder Coat.
Show Photo
Monitored Outlet Level 60/63A 240/415V WYE 19in / 483mm 10ft / 3m IEC Splashproof
  • Combination C13/C19 (24)
Y N Y N