Part # | Model # | Type | Sub Category | Amps | Volts | Rackmount Length | Cord Length | Plug Type | Receptacle (QTY) | Local Meter | Universal | Upgradeable | RCM-B | ||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
VP6U60A3 | JMUR5M6Z1-24CF13-6PS56B4A10-S-A |
Show Description
rPDU, Outlet Level Monitoring, 60/63A, 200-240/346-415V WYE, 43.4kW, Vertical, (24) Combination C13/C19, 10ft / 3m power cord with 3P+N+E (IP44), Black Powder Coat.
|
Monitored | Outlet Level | 60/63A | 240/415V WYE | 72in / 1829mm | 10ft / 3m | IEC Splashproof |
|
Y | N | Y | N | |
VP6U60A2 | JMUR5MIZ1-36CF13-6PS56B4A10-S |
Show Description
rPDU, Outlet Level Monitoring, 60/63A, 200-240/346-415V WYE, 43.4kW, Vertical, (36) Combination C13/C19, 10ft / 3m power cord with 3P+N+E (IP44), Black Powder Coat.
|
Monitored | Outlet Level | 60/63A | 240/415V WYE | 66in / 1683mm | 10ft / 3m | IEC Splashproof |
|
Y | N | Y | N | |
VP6U60A1 | JMUR5MDZ1-48CF13-6PS56B4A10-S |
Show Description
rPDU, Monitored Outlet Level, 60/63A, 200-240/346-415V WYE, 43.4kW, Vertical, (48) Combination C13/C19, 10ft / 3m power cord with 3P+N+E (IP44), Black Powder Coat.
|
Monitored | Outlet Level | 60/63A | 240/415V WYE | 83in / 2115mm | 10ft / 3m | IEC Splashproof |
|
Y | N | Y | N | |
VP6U60A0 | MUR5MHW1-36CF17-6PS6B4A10-S |
Show Description
rPDU, Monitored Outlet Level, 60A/63A, 200-240V, 14.4kW, Vertical, (36) Combination C13/C19, 10ft / 3m power cord with 1P+N+E (IP44), Black Powder Coat.
|
Monitored | Outlet Level | 60/63A | 200-240V | 70in / 1778mm | 10ft / 3m | IEC Splashproof |
|
Y | N | Y | N | |
VP6NA0A0 | JMNR5MIZ1-24CF18-8HW15A9BXX-S |
Show Description
rPDU, Monitored Outlet Level, 80A, 208V Delta, 28.8kW, Vertical, (24) Combination C13/C19, Hardwired, Black Powder Coat.
|
Monitored | Outlet Level | 80A | 208V DELTA | 66in / 1683mm | None | Hardwired |
|
Y | N | Y | N | |
VP5UA0A0 | JMUS5MIZ1-36CF13-8HW56A9BXX-S |
Show Description
rPDU, Switched Unit Level Monitoring, 80A, 200-240/346-415V WYE, 57.6kW, Vertical, (36) Combination C13/C19, Hardwired, Black Powder Coat.
|
Switched | Unit Level Monitoring | 80A | 240/415V WYE | 66in / 1683mm | None | Hardwired |
|
Y | N | Y | N | |
VP5U62A2 | JMUS5MZA1-24CF13-6PS56B4H10-S-A |
Show Description
rPDU, Switched Unit Level Monitoring, 60/63A, 200-240/346-415V WYE, 43.4kW, Horizontal, (24) Combination C13/C19, 10ft / 3m power cord with 3P+N+E (IP44), Black Powder Coat.
|
Switched | Unit Level Monitoring | 60/63A | 240/415V WYE | 19in / 483mm | 10ft / 3m | IEC Splashproof |
|
Y | N | Y | N | |
VP5U62A0 | MUS5MDR6-24CF17-6PS6H4A10-S |
Show Description
rPDU, Switched Unit Level Monitoring, 60A/63A, 200-240V, 14.4kW, Horizontal, (24) Combination C13/C19, 10ft / 3m power cord with 1P+N+E (IP44), Black Powder Coat.
|
Switched | Unit Level Monitoring | 60/63A | 200-240V | 19in / 483mm | 10ft / 3m | IEC Splashproof |
|
Y | N | Y | N | |
VP5U60A3 | JMUS5M6Z1-24CF13-6PS56B4A10-S-A |
Show Description
rPDU, Switched Unit Level Monitoring, 60/63A, 200-240/346-415V WYE, 43.4kW, Vertical, (24) Combination C13/C19, 10ft / 3m power cord with 3P+N+E (IP44), Black Powder Coat.
|
Switched | Unit Level Monitoring | 60/63A | 240/415V WYE | 72in / 1829mm | 10ft / 3m | IEC Splashproof |
|
Y | N | Y | N | |
VP5U60A2 | JMUS5MIZ1-36CF13-6PS56B4A10-S |
Show Description
rPDU, Switched Unit Level Monitoring, 60/63A, 200-240/346-415V WYE, 43.4kW, Vertical, (36) Combination C13/C19, 10ft / 3m power cord with 3P+N+E (IP44), Black Powder Coat.
|
Switched | Unit Level Monitoring | 60/63A | 240/415V WYE | 66in / 1683mm | 10ft / 3m | IEC Splashproof |
|
Y | N | Y | N | |
VP5U60A1 | JMUS5MDZ1-48CF13-6PS56B4A10-S |
Show Description
rPDU, Switched Unit Level Monitoring, 60/63A, 200-240/346-415V WYE, 43.4kW, Vertical, (48) Combination C13/C19, 10ft / 3m power cord with 3P+N+E (IP44), Black Powder Coat.
|
Switched | Unit Level Monitoring | 60/63A | 240/415V WYE | 83in / 2115mm | 10ft / 3m | IEC Splashproof |
|
Y | N | Y | N | |
VP5U60A0 | MUS5MHW1-36CF17-6PS6B4A10-S |
Show Description
rPDU, Switched Unit Level Monitoring, 60A/63A, 200-240V, 14.4kW, Vertical, (36) Combination C13/C19, 10ft / 3m power cord with 1P+N+E (IP44), Black Powder Coat.
|
Switched | Unit Level Monitoring | 60/63A | 200-240V | 70in / 1778mm | 10ft / 3m | IEC Splashproof |
|
Y | N | Y | N | |
VP5NA0A0 | JMNS5MIZ1-24CF18-8HW15A9BXX-S |
Show Description
rPDU, Switched Unit Level Monitoring, 80A, 208V Delta, 28.8kW, Vertical, (24) Combination C13/C19, Hardwired, Black Powder Coat.
|
Switched | Unit Level Monitoring | 80A | 208V DELTA | 66in / 1683mm | None | Hardwired |
|
Y | N | Y | N | |
VP4UV0A3 | DU05M5B1-48CF17-2S02A9K00-S-A |
Show Description
rPDU, Monitored Unit Level EC, 22.0kW, Variable Power Configuration, Vertical, (48) Combination C13/C19, Universal Inlet, Black Powder Coat.
|
Monitored | Unit Level | Variable | Variable | 66in / 1683mm | None | Universal Input |
|
Y | Y | Y | N | |
VP4UV0A2 | DU05M4B1-30CF17-2S02A9K00-S-A |
Show Description
rPDU, Monitored Unit Level EC, 22.0kW, Variable Power Configuration, Vertical, (30) Combination C13/C19, Universal Inlet, Black Powder Coat.
|
Monitored | Unit Level | Variable | Variable | 66in / 1683mm | None | Universal Input |
|
Y | Y | Y | N | |
VP4UV0A1 | MU05M4W0-42PZ67-2C20A9A00-S |
Show Description
rPDU, Monitored Unit Level EC, 16A OR 20A, 120V OR 208V OR 230V, 1.9kW or 3.3kW or 3.6kW, Vertical, (36) Locking IEC C13, (6) Locking IEC C19, C20 Inlet, Black Powder Coat.
|
Monitored | Unit Level | 16A OR 20A | 120V or 208V or 230V | 72in / 1829mm | None | IEC |
|
Y | N | Y | N | |
VP4UU0A1 | DU05M4W1-42CF17-1S02A9K00-S-A |
Show Description
rPDU, Monitored Unit Level EC, 11.0kW, Variable Power Configuration, Vertical, (42) Combination C13/C19, Universal Inlet, Black Powder Coat.
|
Monitored | Unit Level | Variable | Variable | 70in / 1778mm | None | Universal Input |
|
Y | Y | Y | N | |
VP4UA0A1 | MU05M5B1-36CF13-8HW56A9BXX-S |
Show Description
rPDU, Monitored Unit Level, 80A, 200-240/346-415V WYE, 57.6kW, Vertical, (36) Combination C13/C19, Hardwired, Black Powder Coat.
|
Monitored | Unit Level | 80A | 240/415V WYE | 66in / 1683mm | None | Hardwired |
|
Y | N | Y | N | |
VP4U62A1 | MU05MDR1-24CF13-6PS56B4H10-S-A |
Show Description
rPDU, Monitored Unit Level, 60/63A, 200-240/346-415V WYE, 43.4kW, Horizontal, (24) Combination C13/C19, 10ft power cord with 3P+N+E (IP44), Black Powder Coat.
|
Monitored | Unit Level | 60/63A | 240/415V WYE | 19in / 483mm | 10ft | IEC Splashproof |
|
Y | N | Y | N | |
VP4U62A0 | MU05MDR1-24CF17-6PS6B4H10-S |
Show Description
rPDU, Monitored Unit Level, 60A/63A, 200-240V, 14.4kW, Horizontal, (24) Combination C13/C19, 3m power cord with 1P+N+E (IP44), Black Powder Coat.
|
Monitored | Unit Level | 60/63A | 200-240V | 19in / 483mm | 10ft / 3m | IEC Splashproof |
|
Y | N | Y | N |