The Monitored and Switched PDU offers real-time power consumption monitoring including voltage, real power, apparent power, power factor, amps and kilowatt hours via secure web interface, SNMP or SSH along with the ability to remotely turn on, turn off, or reboot power at each outlet.

The PDUs are available in the following configurations: unit-level or outlet-level power monitoring and control.

Our PDUs offer important insights on how to improve data center energy efficiency while enabling you to prevent downtime, providing notifications when user-specified thresholds for power and climate conditions are breached.

Tabs

Overview

Intelligence

Outlet Level Monitoring and Control PDUs Intelligence
Intelligence

1. USB

Functionality What it means for you
Integrate USB Flash Drive Enhance data logging capacity
Perform firmware updates and backup/restore of PDU configuration via USB stick. Provides alternate method for updating firmware across PDUs as well backing up and restoring configuration as needed.
Integrate approved 802.11 WiFi module Eliminate the hassle that comes with cable management and deploy your PDUs faster.

 

2. Dual Ethernet Ports

Functionality What it means for you
Allows fault-tolerant daisy chaining of multiple devices. Daisy-chain PDUs together while ensuring connectivity with Rapid Spanning Tree Protocol support.

 

3. Environmental Monitoring

Functionality What it means for you
Interface a variety of plug-n-play sensors Monitor rack-level temperature, humidity, airflow, door position, leak detection and more.

 

4. VLC Display

Functionality What it means for you
Displays user-configurable real-time metrics Display real-time info useful in determining circuit load status and balancing
Visible Light Communication (VLC) Optically scan data from the PDU LED Display to a handheld device over the Geist App to provide comprehensive phase and circuit level data at your fingertips.

 

Hardware

Hardware - Mechanical

Alternating Phase/Outlet Configuration

Functionality What it means for you
Arrange outlets in a Phase A,B,C order on the PDU. Simplified load balancing for high density cabinets

 

Smart Latching Relay

Functionality What it means for you
Bi-stable relays are magnetically latched and do no need continuous power to hold the contacts closed (or open), saving significant energy compared to traditional switching PDUs Reduce power consumption
Power State sensing ensures the relays are de-latched if the power fails allowing power on sequencing when the power is reapplied. Power-on sequencing

 

High Density Outlet Configurations

Functionality What it means for you
PDUs available with up to 36 C-13 outlets in a single width, 72 inch chassis Optimize available cabinet space with the ability to add more equipment in high density environments.

 

Upgradeable

Functionality What it means for you
Hot-swappable and field-upgradeable Interchangeable Monitoring Device (IMD) Buy for current needs and upgrade as necessary based on changing customer requirements or as technology continues to evolve.

 

U-Lock Receptacles

Functionality What it means for you
Interlocks standard C-13 and C-19 cord sets withstanding 45 pounds of force. Prevents unintentional dislodging of power cords, ensuring uptime and reliability.

 

Low Profile Breakers (select PDUs)

Functionality What it means for you
Protect damage caused by overcurrent, typically resulting from an overload or short circuit. Offers greater flexibility in scenarios where space is limited at the back of the rack for installation. Reduce depth in certain configurations.

 

Software

Software

Outlet Level Monitoring

Functionality What it means for you
Individual outlet level monitoring for a detailed view of the power distributed to specific equipment. Analyze power trends and perform capacity planning.

 

Outlet Level Control

Functionality What it means for you
Remote control of individual outlet including on, off, reboot. Increase runtime of critical equipment during power failure by turning off non-essential loads.

 

Data Logging

Functionality What it means for you
Log power metrics over time and export as needed Enables trending analysis to improve decision making with regards to IT infrastructure.

 

Alarming

Functionality What it means for you
Alerts via Email & SNMP when user-specified thresholds are breached. Ability to configure escalating alerts per valid hours and with user-specified alarm delays and repeats. Prevent downtime by proactively monitoring the power and climate conditions around critical equipment.

 

Periodic Status Reports

Functionality What it means for you
Schedule Emails on an hourly or weekly basis with status of power and environmental conditions. Get timely status reports to proactively monitor and ensure optimum operations.

 

Specifications

Specifications

Input Power Monitoring

Functionality What it means for you
1% Accuracy (ANSI and IEC) Accurately reconcile power usage

 

High Temperature Grade

Functionality What it means for you
60C working ambient variants for high temperature environments.
UL 60C; CE 50C
Easily integrate GU2 PDUs in high density environments

 

Colored Chassis

Functionality What it means for you

Available in black, red, orange, yellow, green, blue and white

 

Easily identify input feeds and minimize downtime-causing errors.

 

Support

Switched PDU Documentation

 
Switched Upgradeable PDU User Manual Download
GU2 Guide Specifications Download

 

Click here for additional product manuals.